Parameters and expressions
Every dimension and feature input is a model parameter (d1, d2, …). User parameters
are ones you add yourself, with a unit, an expression and an optional comment. Change them in
Change Parameters (parameters.change). The timeline rebuilds from the first feature that
uses them.
In the SOLID toolbar’s CONFIGURE panel, click Parameters to open the user and model parameter editor. The separate Configurations button opens the configuration table; Configure remains in the dropdown for configuring columns.
Press Enter in the new parameter’s name, expression or comment field to add it. Valid entries return focus to the name field for the next parameter; invalid entries remain editable. In expression fields, type a parameter or dimension name for autocomplete, or press Ctrl+Space to open suggestions, including in an empty field. Up/Down selects an autocomplete suggestion, Enter/Tab accepts it, and Escape dismisses the suggestions. Accepting a suggestion does not also submit the parameter.
Expressions are unit-aware: 2 * width + 5 mm, angle / 2, sqrt(area), 1 in + 3 mm, using
+ - * / ^, parentheses, sin cos tan asin acos atan atan2 sqrt abs min max floor ceil round mod trunc and unit conversion. A decimal comma works too, outside parentheses: 2,5 mm is
2.5 mm (inside a function’s parentheses the comma separates its arguments, so write
max(2.5, 3) there). A mixed number is one value, as imperial sizes are written: 2 1/8" and
3 7/16 in are 2.125 in and 3.4375 in (a whole number, a space, then a proper fraction of whole
numbers). A length where an angle is expected (or the other way round) is an
error, not a silent conversion. Cycles are reported with their path (a → b → a), renaming a
parameter updates every expression, dimension and feature input that uses it, and a parameter
in use can’t be deleted (the error lists its users).
The design’s units (Document Settings in the browser: mm, cm, m, in or ft) set how a bare number
typed into a feature is read. In an inch design 2 means 2 in. The Box, Cylinder, Sphere, Torus
and Coil dialogs start with their sizes in the design’s units, unit shown (20 mm, 20 in).
Changing the units never moves existing geometry. A size worked out from a bare number keeps
the unit the number was given in: a sphere with a bare diameter of 20 has the radius
(20 mm) / 2 in a millimetre design. Beside a unit-less expression such as 2 * 5 or a
unit-less parameter, which is read in the design’s units, the number stays bare and is read
with it.
Parameters export to and import from CSV or JSON (parameters.export, parameters.import).
Configurations (config.*) keep a table of rows, each with its own parameter values and
suppressed features, physical materials and body appearances, switched with config.activate.
The table’s Library picker selects material or appearance values. Choose Follow material
to clear an appearance override. Custom looks retain their colour and opacity across
activation, undo and save/reopen. See
configuration commands and examples.